Your privacy, your choice

We use essential cookies to make sure the site can function. We also use optional cookies for advertising, personalisation of content, usage analysis, and social media.

By accepting optional cookies, you consent to the processing of your personal data - including transfers to third parties. Some third parties are outside of the European Economic Area, with varying standards of data protection.

See our privacy policy for more information on the use of your personal data.

for further information and to change your choices.

Skip to main content

Table 6 Cox regression models for cumulative all-cause mortality after off-pump coronary artery bypass graftinga

From: Intraoperative mild hyperoxia may be associated with improved survival after off-pump coronary artery bypass grafting: a retrospective observational study

 

Univariable

P

Multivariable 1b

P

Multivariable 2c

P

HR (95% CI)

HR (95% CI)

HR (95% CI)

Normoxia/near-normoxia

Reference

 

Reference

 

Reference

 

Mild hyperoxia

0.69 (0.51–0.93)

0.016

0.82 (0.60–1.11)

0.199

0.72 (0.52–0.99)

0.048

Severe hyperoxia

1.12 (0.72–1.74)

0.627

1.41 (0.89–2.24)

0.141

1.05 (0.65–1.69)

0.851

  1. HR Hazard ratio, CI Confidence interval
  2. aTwenty-two patients were not included because their survival data were not available
  3. bModel 1 was adjusted for variables consisting of the European System for Cardiac Operative Risk Evaluation II model (see the “Methods” section)
  4. cModel 2 was adjusted for all variables used in model 1 and demographic data and perioperative variables listed in Table 1 (see the “Methods” section)