Skip to main content

Table 7 Results of ROC curve analysis

From: Clinical value of NT-proBNP, MPO, and NLR combined with echocardiography in prediction of malignant arrhythmia in elderly patients with valvular heart disease

Test result variable (s)

Area

Std. error

P

Asymptotic 95% confidence interval

  

Cut-off value

    

Lower bound

Upper bound

Sensitivity

Specificity

 

MPO

0.759

0.092

0.006

0.579

0.938

0.692

0.811

134.59 mg/L

NT-proBNP

0.782

0.078

0.003

0.630

0.934

0.615

0.946

765.57 ng/L

NLR

0.736

0.089

0.012

0.562

0.910

0.769

0.649

5.720

Echocardiography

0.782

0.069

0.003

0.646

0.918

0.769

0.757

 

The four combined

0.913

0.047

0.000

0.814

1.000

0.769

0.946

 
  1. ROC Receiver Operator Characteristic, NT-proBNP N-terminus pro-brain natriuretic peptide, MPO Myeloperoxidase, NLR Neutrophil–Lymphocyte Ratio